See How Many Clients You're Missing Each Month

Simply enter your business email & Topline AI Agent will show you.

Bio

Generated by
Topline AI

Experience

  • NUR Power
    • Kulim, Kedah, Malaysia
    • Primary Equipment Maintenance Engineer (Electrical)
      • Jan 2024 - Present
      • Kulim, Kedah, Malaysia

      Electrical Engineer at Kulim Hi-Tech Park, Kedah.

    • Electrical & Instrument Site Engineer
      • Jul 2022 - Apr 2024
      • Kulim, Kedah, Malaysia

      Electrical & Instrument Site Engineer and Client's Representative at new plant Osram FEK 2, Kulim Hi-TechResponsible for all packages contractors under Electrical thread.

  • Auconpro Engineering Sdn Bhd
    • Subang Jaya, Selangor, Malaysia
    • Electrical Design Engineer
      • Dec 2019 - Dec 2022
      • Subang Jaya, Selangor, Malaysia

      As an electrical design engineer, I am working with client that is TNB. My responsibilities is doing the design of the protection and control of TNB substation or PMU from voltage level 400V up to 132kV. Most of the job involved such as retrofitting old relay control panel at substation, where i need to replace old scheme to new scheme (Low Impedance BBP), replace old protection relay (Current Diff, Distance, Auto Reclose, REF, Breaker Failure), upgrading old scheme to new scheme(RTU, SCS, Synchronisation panel) and modification of control and protection circuit. Other task is doing site visit for data collection, CAD drawing for new circuits, submission and approval by Client TNB, procurement and preparation of materials and lead the sitework for installation and commmissioning. Lastly is preparation of as built drawing to handover to Client. For management task, I need to prepare work schedule, progress report, MOS presentation, attend meetings manage subcontractors and verify of claims as well as control budget. I also work closely with competent engineer(CE) and received delegation of permit to work from CE at site.

    • Electrical Design Engineer
      • Apr 2019 - Nov 2019

      Design 33kV Gas Insulated Switchgear(GIS) for PMU Inanam project 132/33/11kV at SESB.-prepare primary equipment and schematic drawing based on requirement from SESB.Prepare drawing which involve with GIS for tender submission, extension project and modification project.Prepare drawing of Ring Main Unit for tender submission.Testing, commissioning and troubleshooting at switchgears.

  • Testcom Services Sdn Bhd
    • Selangor, Malaysia
    • Testing and Commissioning Engineer
      • Apr 2017 - Apr 2019
      • Selangor, Malaysia

      1)PETRONAS RAPID PROJECT- CONSTRUCTION & COMMISSIONING OF MAIN SUBSTATION (JULY 2017-MARCH 2019)-Currently as a Testing Engineer for (Package 14-Utilities, Interconnecting and Offsite) at Pengerang, Johor. -Responsible to lead testing(s) work(SAT), prepare result, report progress to client and commissioning manager, liase or deal with vendors (ABB, Schneider, Siemens India, Siemens Malaysia, Siemens China, Borri) and construction parties, finding solution to solve problem at site, electrical troubleshooting at switchgears, find and clear any defects or punchlist, final inspection prior to commissioning and etc.(1) Sub 401 GIS 275/33/0.4 kV (2) Sub 101 GIS 33/0.4 kV(3) Sub 102 GIS 33/0.4 kV (4) Sub 402 GIS 33/0.4 kV(5) Sub 301 GIS 275/33/11/0.4 kV (6) Sub 302 GIS 275/33/11/0.4kV-Have performed primary equipment testing that are current transformer, voltage transformer, circuit breaker, disconnecting switches, neutral grounding resistor, surge arrestor, functional of gas insulated switchgear, 275/33kV @ 33/11kV and 11/0.4kV power transformer.-Secondary equipment testing done are protection relay callibration, interlocking, wiring check local/remote, indication, automatic voltage regulator, metering panel and etc. -Scheme / functional test are also done that are stability of transmission lines, transformers, high voltage restricted earth fault, low voltage restricted earth fault, busbar differential protection, earth fault, overcurrent, transformer guard, ac pressure test, signal exchance and intertrip signal.-Lead for commissioning ABB low voltage switchboard, low voltage auxiallary system at substation consist of AC UPS, DC UPS, Utility Distribution Panel, Remote Tap Changer Control Panel, Local Control Panel for Power Transformer, Revenue Metering Panel, 33kV & 275kV auxiallary power supply.-Commissioning all Main Substation, Unit Substation & Emergency Diesel Generator(EDG) station.Manufacturer : Siemens, Schneider, ABB, Borri, Eaton.

    • Trainee
      • Jun 2015 - Sep 2015

      Testing and Commisioning

    • Trainee
      • Nov 2012 - Feb 2013

Education

  • 2010 - 2016
    Universiti Malaysia Perlis
    Electrical Engineering
  • 2005 - 2009
    SMK Baling, Kedah

Suggested Services

This profile is unclaimed. These are suggested service rates with 0% commision upon successful connection

Industry Focus. “Utilities”

Looking to Create a Custom Project?

Need a custom project? We'll create a solution designed specifically for your project.

Get Started

References

Social Profiles

Community

You need to have a working account to view this content. Click here to join now

Similar Profiles