Matthew Deslauriers
Energy Consultant 2 at VEIC- Claim this Profile
Click to upgrade to our gold package
for the full feature experience.
Topline Score
Bio
Experience
-
VEIC
-
United States
-
Non-profit Organizations
-
200 - 300 Employee
-
Energy Consultant 2
-
Sep 2021 - Present
-
-
-
West Hill Energy and Computing, Inc.
-
Oil and Gas
-
1 - 100 Employee
-
Senior Energy Engineer
-
Oct 2017 - Sep 2021
Conducted AMI, billing, and meter analyses for natural gas, electricity, and unregulated fuels Performed residential and commercial site visits to meter heat pump water heaters, heat pumps, lighting, fans, pumps, and refrigeration ECMs Conducted AMI, billing, and meter analyses for natural gas, electricity, and unregulated fuels Performed residential and commercial site visits to meter heat pump water heaters, heat pumps, lighting, fans, pumps, and refrigeration ECMs
-
-
-
Sabbatical & Travel
-
Travel Arrangements
-
1 - 100 Employee
-
Global Travel Sabbatical
-
Aug 2016 - Aug 2017
-
-
-
Vanderweil Engineers
-
United States
-
Engineering Services
-
300 - 400 Employee
-
Senior Energy Engineer
-
Mar 2014 - Aug 2016
Utilized eQuest and custom spreadsheet based energy estimating tools to efficiently develop energy analyses and sustainable solutions for new and existing projects in all phases of design Guided a team of junior energy engineers to develop their energy modeling proficiency Accelerated workflow through sharing best practices. Best practices include: identifying the best tool for the job, standardizing model structure, collaborating with other teams to accelerate data collection, using BDL code in eQuest, creating Python scripts, and utilizing INP file RegEx find and replace edits Modeled complex HVAC systems including: ground source heat pumps, chilled beams, DOAS, laboratory exhaust, displacement ventilation, VRF, dual energy recovery wheels, wrap around heat pipes, and heat recovery chillers Designed and co-developed custom energy data analysis tools to identify the best areas to reduce energy use, to troubleshoot and quality check models, to quantify ECMs, to address LEED submissions, and to benchmark designs Constructed CFD simulations with Cradle scStream to analyze the performance of HVAC systems Simulated daylighting and glare analysis conditions using Ecotect and Radiance Show less
-
-
-
EYP
-
United States
-
Architecture and Planning
-
200 - 300 Employee
-
HVAC Engineer, ECO-Facilitator
-
Jun 2008 - Mar 2014
Designed and witnessed the implementation of numerous complex green HVAC system designs Collaborated on nine LEED project submissions and the development of their HVAC systems Conducted energy modeling using eQuest and Trane Trace Jointly led and helped develop a firm-wide sustainability program called EYP Planet, introducing new policies and measurements to six offices to reduce waste and cut energy use in the company's operations and designs Progressed and jointly led the AIA 2030 program which tracked the estimated energy use of the firm's designs Initiated coordination and led the advancement of the HVAC Revit Template for the company Show less
-
-
Education
-
University of Massachusetts Amherst
Bachelor of Science (BS), Mechanical Engineering