Tran Do, R.T.(T)(R), CMD

Medical Dosimetrist at NEW YORK UNIVERSITY LANGONE MEDICAL CENTER
  • Claim this Profile
Contact Information
us****@****om
(386) 825-5501
Location
Upper Darby, Pennsylvania, United States, US
Languages
  • English -
  • Vietnamese -

Topline Score

Topline score feature will be out soon.

Bio

Generated by
Topline AI

You need to have a working account to view this content.
You need to have a working account to view this content.

Credentials

  • Radiation Therapist
    ARRT
    Nov, 2014
    - Oct, 2024
  • X-Ray Technician
    ARRT
    Aug, 2017
    - Oct, 2024
  • Medical Dosimetrist (CMD)
    MEDICAL DOSIMETRIST CERTIFICATION BOARD

Experience

    • United States
    • Medical Practices
    • 1 - 100 Employee
    • Medical Dosimetrist
      • May 2020 - Present

      • Work closely with physicians, therapists and medical physicists to design and optimize photon and electron treatment plans, using Eclipse (ver. 15.6), in compliance with the physician’s prescription• Obtain, interprets and use patient-specific data to plan and ensure all pertinent information pertaining to the plan is communicated to the treatment delivery team through EPIC and Aria (ver.15)• Fuse and contour OARs of all sites using CT, MRI and PET imaging modalities• Create QA plans using ArcCheck and MapCheck for patient specific need• Utilize care paths to maintain and manage work efficiency to ensure tasks are completed and proper documentation is provided in a timely manager prior to the patient’s start date• Assist HIM in importing and exporting prior treatment records using Life Image• Collaborate with physicists to update and enforce physics initiatives, policies and procedures • Participate in projects to aid in increasing departmental efficiency• Train medical residents, dosimetrists, and physics residents in treatment planning• Serve as a member of the clinical protocol team to update and ensure proper data complies as per protocols• Submit bills for services rendered• Participate and present in Chart Rounds

    • United States
    • Higher Education
    • 700 & Above Employee
    • Medical Dosimetrist
      • Jul 2016 - May 2020

      • Designed and optimized 3DCRT, IMRT, VMAT, SBRT and electron plans for various anatomical sites including H&N, abdomen, pelvis, lung, brain, breast and extremities using Eclipse (ver. 15.5) for varies machines such as Truebeam, Halcyon, and Clinacs• Worked closely with proton planners to assist in cases that required back up plans, mixed modalities, and/or needed insurance comparison plans• Used MIM to transfer target volumes and contour OARs• Cooperated with therapists and physicians in Acuity for clinical setups and at time of simulation for complicated setups to determine the optimal use of immobilization devices as per patient need• Assisted in planning for main campus (PCAM) as well as satellite centers as needed• Utilized PENN MU for dosimetric calculation of clinical electron, TBI, and TSET plans• Prepared and presented talks in departmental staff meetings and yearly physics lectures• Assisted in the implementation of programs such as RapidPlans, EZ Fluence, and Halcyon planning• Represented Dosimetry and actively participate as a Super User in the Aria Workgroup meetings

    • Medical Dosimetrist
      • Feb 2016 - Jul 2016

      • Developed optimal computerized treatment plans using the Eclipse (ver. 11) treatment planning system• Utilized AdvantageSim simulation and localization software• Created and measured electron cutouts and their outputs• Entered and verified dosimetric plan parameters in Aria (ver. 11) verification• Created verification plans and participate in patient specific quality assurance• Assist physics in weekly and monthly chart checks • Developed optimal computerized treatment plans using the Eclipse (ver. 11) treatment planning system• Utilized AdvantageSim simulation and localization software• Created and measured electron cutouts and their outputs• Entered and verified dosimetric plan parameters in Aria (ver. 11) verification• Created verification plans and participate in patient specific quality assurance• Assist physics in weekly and monthly chart checks

    • Medical Dosimetrist Intern
      • Sep 2014 - Aug 2015

      • Generated optimal 3DCRT, IMRT, VMAT, SRS, SBRT and electron plans• Utilized RadCalc and MOSAIQ (ver. 2.6) • Assisted in CT simulations and setups• Designed beam modifying devices• Instructed Radiation Therapy students on basic dosimetry

    • Radiation Therapy Intern
      • Sep 2013 - Aug 2014

      • Operated Varian linear accelerators such as the Truebeam, Trilogy and 2100C • Performed simulations on a GE Computer Tomography Scanner with Varian’s RPM system • Participated in Brachytherapy procedures • Performed daily and monthly quality assurance procedures

    • Hospitals and Health Care
    • 400 - 500 Employee
    • Radiography Intern
      • Sep 2012 - Aug 2013

      • Implemented radiation protection and safety standards• Performed all diagnostic radiography examinations• Operated stationary and mobile radiography units • Implemented radiation protection and safety standards• Performed all diagnostic radiography examinations• Operated stationary and mobile radiography units

Education

  • Thomas Jefferson University
    Bachelor's degree, Radiologic Science - Medical Dosimetrist
    2014 - 2015
  • Thomas Jefferson University Hospitals
    Bachelor's degree, Radiologic Science - Radiographer & Radiation Therapist
    2012 - 2013

Community

You need to have a working account to view this content. Click here to join now