Shoukat Ali (MS, DIMPCB)

Chief Medical Physicist at Sindh Institute of Urology and Transplantation
  • Claim this Profile
Contact Information
us****@****om
(386) 825-5501
Location
Pakistan, PK
Languages
  • English -

Topline Score

Topline score feature will be out soon.

Bio

Generated by
Topline AI

You need to have a working account to view this content.
You need to have a working account to view this content.

Experience

    • Pakistan
    • Hospitals and Health Care
    • 300 - 400 Employee
    • Chief Medical Physicist
      • Nov 2019 - Present

      Acceptance testing and commissioning of a Elekta Versa HD linear accelerator i) Photon Energies 6MV, 10MV and 15MV, 6MVFFF, 10MVFFF ii) Electron Energies 6MeV, 8MeV, 10MeV, 12MeV, 15MeV Acceptance testing and commissioning of a Elekta Versa HD linear accelerator i) Photon Energies 6MV, 10MV and 15MV, 6MVFFF, 10MVFFF ii) Electron Energies 6MeV, 8MeV, 10MeV, 12MeV, 15MeV

    • Pakistan
    • Hospitals and Health Care
    • 700 & Above Employee
    • Senior Medical Physicist
      • Jan 2018 - Oct 2019

      Treatment Planning Systems: 1. Eclipse System V 10.0 (3DCRT,IMRT), V15.5 2. Find manually the dose at different depths by using the TAR and PDD method and their relationship. Dosimetry Experience: 1. Beam data acquisition of 6 & 18 MV beams for commissioning of AAA algorithm 2. Verification of beam data for treatment planning systems Quality Assurance; a. Weekly and Monthly quality assurance of simulator and linear accelerators. b. Calibration of Ir-192 high dose rate brachytherapy source. c. Patient specific QA of IMRT patients d. Patient specific QA with MU Calc. e. TBI patient 2. Treatment Planning; f. 3DCRT and 2D plannings g. IMRT planning h. Brachytherapy planning i. Special procedure; TBI, TSET 3. Radiation Protection; j. Radiation survey Publications: 1. In vivo dosimetry with diodes in a radiotherapy department from Pakistan Radiat Prot Dosimetry. 2011 Jan 2. PMID: 21199828 2. Influence of CT Slice Thickness on Volume and Dose Uncertainty for Different Organs during Treatment Planning For Early Prostate Cancer Pjr April - June 2010; 20(2): 87-91 3. Single Institutional Experience of Electron Conformal Therapy (ECT) and Modulated Electron Therapy (MET) for Postmastectomy Chest Wall Irradiation Journal of Radiotherapy in Practice (2012) 0, 1_7 4. An Assessment of Medical Physics Knowledge of Undergraduate Physics Students The Nucleus 53, No. 4 (2016) 233-235 Show less

    • Pakistan
    • Higher Education
    • 700 & Above Employee
    • Medical Physicist
      • Apr 2013 - Dec 2017

    • Medical Physicist
      • Feb 2009 - Apr 2013

      Working on:1. Virtual (CT) Simulator (Siemens Somatom Emotion 6)2. Linear accelerator (Siemens Oncor) i) Photon Energies 6MV, 15MV ii) Electron Energies 6MeV, 9MeV, 12MeV, 15MeV, 18MeV, 21MeV iii) Multi leaf Collimator (MLC’s) 29-Pairs iv) Electronic Portal Imaging Device (EPID)3). Isodose Control (Nucletron) HDR MachineThree Diementional Treatment Planning Experience:Siemens Coherence Dosimetrist (For contouring and Beam Shaping) 2. Prowess Panther System V 4.2 (3DCRT)3. Siemens Lantis System4. Flexiplan System V 2.2,2.6 (Brachytherapy Planning System)5. Find manually the dose at different depths by using the TAR and PDD method and their relationship.Dosimetry Equipments:1. Relative and Absolute Dosimetry 3-D Dosimetry System (IBA WELLHOFER SCANDITRONIX)2. Relative Dosimetry (PHANTOM PMMA)3. Air kerme Strength (WELL TYPE ION CHAMBER) For Ir-192 Source Teaching Experience:• Teach the doctors of the FCPS courses• Develop the Continuous Professional Development (CPS) Program for all the Radiation WorkerAcceptance testing and commissioning of a Elekta Synergy linear acceleratori) Photon Energies 6MV, 10MV and 18MVii) Electron Energies 6MeV, 8MeV, 10MeV, 12MeV, 15MeV Shielding design:To Verify Shielding Design of Bunker for High Energy (6MV &15MV) Linear Accelerator and Cobalt-60 Telatherapy Unit according to the NCRP-151 report. Show less

    • Medical Physicist
      • Feb 2009 - Apr 2013

      Medical Physicist-I in Sindh Institute of Urology and Transplantation (SIUT) Karachi Pakistan from Feb, 2010 to till date April,2013Medical Physicist (Trainee) in Sindh Institute of Urology and Transplantation (SIUT) Karachi Pakistan from Feb 16, 2009 to January,2010

    • Trainee Medical physicist
      • Feb 2009 - Jan 2010

      Excellent ability to analyzed the problem and develop the solution under the physics paradigm. Well developed analyzing and problem solving skills. Good under standing of modern physics. Have got great interest in Mathematics and physic that aid me devise solutions for the most complex problems. Have excellent potential to work under the critical circumstances Excellent ability to analyzed the problem and develop the solution under the physics paradigm. Well developed analyzing and problem solving skills. Good under standing of modern physics. Have got great interest in Mathematics and physic that aid me devise solutions for the most complex problems. Have excellent potential to work under the critical circumstances

Education

  • NED University of Engineering and Technology
    Master of Science (MS), Physics
    2013 - 2016
  • University of Karachi
    Master of Science (MSc), Nuclear Physics
    2004 - 2008
  • National college Pakistan
    FSC (Pre Eng), Engineering
    2002 - 2004
  • St pauls high school
    Matericulation, 2001
    1999 - 2001

Community

You need to have a working account to view this content. Click here to join now