Naresh Kumar Angappan

Assistant Manager Electrical at NAGAI POWER PRIVATE LIMITED
  • Claim this Profile
Contact Information
us****@****om
(386) 825-5501
Location
Karaikal, Puducherry, India, IN

Topline Score

Topline score feature will be out soon.

Bio

Generated by
Topline AI

You need to have a working account to view this content.
You need to have a working account to view this content.

Credentials

  • Electrical C license holder
    Electrical Licensing Board
    Jun, 2019
    - Nov, 2024

Experience

    • Utilities
    • 1 - 100 Employee
    • Assistant Manager Electrical
      • Sep 2018 - Present

    • Senior Electrical Engineer
      • Sep 2018 - Present

    • Machinery Manufacturing
    • 1 - 100 Employee
    • Senior Electrical Engineer
      • Nov 2016 - Aug 2018

       Synchronization of the plant with the grid.  Generator Protection System having a Protection Relay of Micom P343  Commissioning and maintenance of LT & HT motors up to 6.6kv  Commissioning and Maintenance of HT and LT transformers o 6.6kv/415 V – 1.6 MVA, 2.5 MVA, 2 MVA. o 6.6kv/690 – 3.6 MVA o 230KV/6.6 KV – 12.5 MVA o 230kv/11 KV – 75 MVA  Commissioning and Maintenance of VCB, ACB & SF6 breakers.  Commissioning of Motor operated valve with RDOL Starter circuits.  Commissioning of HT and LT switch gears.  Preparation of report for electrical inspection.  Day, monthly, yearly report preparation.  Trouble shooting of DOL, RDOL, STAR-DELTA starters & EOT Crane.  Trouble shooting of VFD (ACS 800 -ABB) Circuits for 690V PA, SA, and ID Fans Motors and DANFOSS VFD FC-302 for 132Kw Air cooled condenser motor & SIEMENS SINAMICS spare drive for PA fan 750kw commissioning and ID run procedure done.  Trouble shooting of HT & LT Switch Gear Panel Circuits.  Maintenance of Diesel Generator capacity of 625 KVA 870 A 440 V.  Handling the Switch Yard Capacity of 240 KV HT lines and SEMENS make SF6 Breakers ABB make Isolators and CT, PT’s Under the Line Protection of P444 Micom Relay.  Maintenance of Electrostatic Precipitator (ESP) emitting plate rapping motors, collecting plate rapping motors, transformers (415v/95kv) and its oil BDV test.  Maintenance of UPS, Battery bank, Battery Charger and lighting installation. Show less

    • India
    • Consumer Services
    • 1 - 100 Employee
    • Senior Electrical Engineer
      • Nov 2015 - Nov 2016

      Designation : Shift In charge (Operation and Electrical). Client : M/S PARRY SUGARS REFINERY INDIA (P) LTD, KAKINADA Plant Capacity : 10 MW Coal Fired Thermal plant (AFBC boiler) Duration : NOV 2015 to NOV 2016 PLANT DETAILS: A 10MW Thermal power plant having VEESONS make 90 TPH AFBC BOILER, 67Kg/cm2, and SIEMENS Steam Turbine, 10 MW Turbo Generator make TDPS are controlled with WOODWARD Electronic Governor and GE Distributed Control System (DCS) RESPONSIBILITIES:  Efficient operation of the unit, Always pay attention towards plant Heat Rate.  Desk & Field operation of Boiler and Turbine Cold/ Hot start up.  Regular monitoring of utility like De-aerator, Boiler feed pump, CEP, Compressor.  Responsible for plant smooth operations, Control room operations & taking planned start up and shut down procedures as per SOP’s.  Preparing shift activity reports, shift plant generation and coal consumption details.  Maintaining the boiler water and steam parameters through Dosing system and WTP.  To reduce the Downtime of unit and its auxiliaries by avoiding tripping.  Responsible for bringing back the station to normal in station blackout as soon as possible in a safe and efficient manner.  Regular monitoring of Coal plant, Ash handling plant.  Synchronization of the plant with the grid.  Generator Protection System having a Protection Relay of SIEMENS 7UM12  Maintenance of HT and LT transformers o 6.6kv/415 V – 2.5 MVA o 110KV/11 KV – 40 MVA o 11kv/6.9 KV – 12.5 MVA  Day, monthly, yearly report preparation.  Trouble shooting of DANFOSS VFD FC-302 Circuits for 415V 250Kw FD, 45Kw PA, and 110Kw ID Fans Motors and for 2.2Kw drag chain feeder motors.  Maintenance of Electrostatic Precipitator (ESP) emitting plate rapping coils, collecting plate rapping coils, transformers (415v/110kv) and its oil BDV test. Show less

    • India
    • Oil and Gas
    • 300 - 400 Employee
    • Electrical Engineer
      • May 2013 - Nov 2015

      Designation : Electrical Engineer. Client : M/S ARS ENERGY (P) LTD, GUMMIDIPOONDI Plant Capacity : 60 MW Coal Fired Thermal plant (CFBC boiler)  Synchronization of the plant with the grid.  Generator Protection System having a Protection Relay of Micom P343  Commissioning and maintenance of LT & HT motors up to 6.6kv  Commissioning and Maintenance of HT and LT transformers o 6.6kv/415 V – 1.6 MVA, 2.5 MVA, 2 MVA. o 6.6kv/690 – 3.6 MVA o 230KV/6.6 KV – 12.5 MVA o 230kv/11 KV – 75 MVA  Commissioning and Maintenance of VCB, ACB & SF6 breakers.  Commissioning of Motor operated valve with RDOL Starter circuits.  Commissioning of HT and LT switch gears.  Preparation of report for electrical inspection.  Day, monthly, yearly report preparation.  Trouble shooting of DOL, RDOL, STAR-DELTA starters & EOT Crane.  Trouble shooting of VFD (ACS 800 -ABB) Circuits for 690V PA, SA, and ID Fans Motors and DANFOSS VFD FC-302 for 132Kw Air cooled condenser motor & SIEMENS SINAMICS spare drive for PA fan 750kw commissioning and ID run procedure done.  Trouble shooting of HT & LT Switch Gear Panel Circuits.  Maintenance of Diesel Generator capacity of 625 KVA 870 A 440 V.  Handling the Switch Yard Capacity of 240 KV HT lines and SEMENS make SF6 Breakers ABB make Isolators and CT, PT’s Under the Line Protection of P444 Micom Relay.  Maintenance of Electrostatic Precipitator (ESP) emitting plate rapping motors, collecting plate rapping motors, transformers (415v/95kv) and its oil BDV test.  Maintenance of UPS, Battery bank, Battery Charger and lighting installation. Show less

    • Education Management
    • 1 - 100 Employee
    • Graduate Apprentice Trainee
      • May 2012 - May 2013

      Done Apprentice training in M/S CHEMPLAST SANMAR LIMITED, Caustic Lye chemical plant. Done Apprentice training in M/S CHEMPLAST SANMAR LIMITED, Caustic Lye chemical plant.

Education

  • T.J. Institute of Technology
    Bachelor's degree, Electrical and Electronics Engineering
    2007 - 2010
  • The Salem Polytechnic College, salem
    Board of Technical Education, Diploma in Electrical and Electronics Engineering
    2004 - 2007
  • Malco vidyalaya Metric higher sec school
    Mathematics and Computer Science

Community

You need to have a working account to view this content. Click here to join now