Mike Winitzer

Senior Test Engineer at Axsun Technologies
  • Claim this Profile
Contact Information
us****@****om
(386) 825-5501
Location
Billerica, Massachusetts, United States, US

Topline Score

Topline score feature will be out soon.

Bio

Generated by
Topline AI

You need to have a working account to view this content.
You need to have a working account to view this content.

Experience

    • United States
    • Appliances, Electrical, and Electronics Manufacturing
    • 1 - 100 Employee
    • Senior Test Engineer
      • Jul 2017 - Present

    • Test Engineer
      • Feb 2015 - Jul 2017

      Test Engineer • Supported the manufacturing test equipment including repairs and software upgrade for faster test times. • Write programs to query data from a Microsoft SQL server 2008 database using Labview. • Automated grating inspection to store defect data in an Access database, store images in files, and print labels to attach to the inspected parts. • Write test procedures • Train test operators • Participate in kaizen events Test Engineer • Supported the manufacturing test equipment including repairs and software upgrade for faster test times. • Write programs to query data from a Microsoft SQL server 2008 database using Labview. • Automated grating inspection to store defect data in an Access database, store images in files, and print labels to attach to the inspected parts. • Write test procedures • Train test operators • Participate in kaizen events

    • United States
    • Appliances, Electrical, and Electronics Manufacturing
    • 1 - 100 Employee
    • Test Engineer
      • 2006 - 2015

      • Supported the manufacturing test equipment including repairs and upgrades for new products. Implemented SPC for daily test station qualification. • Created a production test station for OCT module test by automating a lab setup using Labview software to control GBIB, Data acquisition PC boards and communicate with a data base using SQL. • Combined three test programs into one saving test and handing time. • Reduced filter test time from 12 minutes to 6 by stream lining test methods. • Replaced sending laser control modules out for calibration with a in house a calibration validation procedure, saving approximately $11000 per year. Show less

  • OPTOVIA
    • Acton Ma
    • Test Engineer
      • 2004 - 2006

      • Designed and supported test systems and characterization for PC Boards and lasers. Wrote programs using Labview software to automate testing using Data Acquisition, GPIB, TCPIP and serial communication. Stored test data in an Access database and coma separated text files. • Tested and debugged pilot runs of PC Boards. • Through Automation lowered the test time of PC Boards from 20 to 6 minutes per board. • Created test system that read test conditions from a multiple page Excel spread sheet to control up to 4 modules. Recorded and displayed over 150 data points per readings. Show less

    • Test Engineer
      • 1994 - 2004

      • With a team of engineers, developed new Laser final test system that interacted with Promis and Oracle. • Wrote Labview state machines to communicate with the Oracle 8I database, PROMIS through SQL and control Profile laser controller through GPIB. Designed new functional test using Labview to control Profile laser controller through GPIB. Interfaced with Oracle through SQL for specification checking and data storage. • Combined AC resistance into functional test, saving on handling and process steps. • Selected to manage production support of the final test station, combined four test code versions into one for easier maintainability. Provided solutions to test engineers on problems related to the development of process equipment. • Wrote a in program Labview to automated the Laser Test Module. Added a data acquisition board to set read signals data collection . Compared the to signals to limits read from a data base then reported status back to operator. Stored the results in a Oracle RDB database • Redesigned the submount burn in station. Reduced burn in board loading from 3 nuts and 4 screws per board to 2 quarter turn cams, reducing loading time from over a minute to under 10 seconds. • Resolved power supply interface problem causing power supplies to overheat and melt, by identifying design flaw and facilitating upgrades resulting in greater reliability of improved equipment. Show less

  • QC OPTICS
    • Burlington, MA
    • Associate Engineer
      • 1986 - 1994

Community

You need to have a working account to view this content. Click here to join now