Michael Knögel

Product Manger Ex d/e Linebushings at Quintex GmbH
  • Claim this Profile
Contact Information
Location
Lauda, Baden-Württemberg, Germany, DE
Languages
  • Deutsch Native or bilingual proficiency
  • Englisch Limited working proficiency

Topline Score

Bio

Generated by
Topline AI

0

/5.0
/ Based on 0 ratings
  • (0)
  • (0)
  • (0)
  • (0)
  • (0)

Filter reviews by:

No reviews to display There are currently no reviews available.

0

/5.0
/ Based on 0 ratings
  • (0)
  • (0)
  • (0)
  • (0)
  • (0)

Filter reviews by:

No reviews to display There are currently no reviews available.
You need to have a working account to view this content. Click here to join now

Experience

    • Germany
    • Appliances, Electrical, and Electronics Manufacturing
    • 1 - 100 Employee
    • Product Manger Ex d/e Linebushings
      • Jan 2017 - Present

      Our line bushings got the IECEx, GOST, CSA, CSA-US, FM and UL approvals and can be used international wide. For the European community (ATEX) and the International Electrotechnical Commission (IECEx), we have an 'X'-approval so that you can use this line bushing in exciting products without a re-approval of your product.Rated Voltage: 440V / 690V / 1000V / 3000V / 6000VConductor size: 0,08mm² to 185mm²Temperature range: -55°C…115°CMax. conductor quantity: up to 55 strandsBushing screwable: Metric-, NPT-, pipe- and special thread up to M72Bushing pluggable: Ø10mm to Ø80mmThread- / pluggable length: >10mmMaterial: Nickel-plated brass, optional stainless steelStandard wire material: Radox 125Unsere Leitungseinführungen haben die ATEX, IECEx, GOST, CSA, CSA-US, FM, UL Zulassungen und sind damit international einsetzbar. Für den ATEX/IECEx Raum haben wir einen 'X-Schein' erwirkt, so daß diese Einführungen auch ohne zusätzliche Prüfung in neue Produkte integriert oder bei bestehenden Produkte andere LD's ersetzen können.Bemessungsspannung: 440V / 690V / 1000V / 3000V / 6000VLitzenquerschnitte: 0,08mm² bis 185mm²Temperaturbereich: -55°C…115°CMaximalbestückung: bis zu 55 LitzenGewindehülse: Metrisches-, NPT-, Rohr- und Sondergewinde bis M72Steckhülse: Ø10mm bis Ø80mmHülsen- / Stecklänge: >10mmHülsenmaterial: Messing vernickelt, optional EdelstahlStandard Litzenmaterial: Radox 125 Show less

    • Product Manager Overpressure Systems certified in accordance to ATEX/IECEx "S"
      • Apr 2007 - Present

      Non-Ex devices can be operated safely in hazardous environments with the help of an overpressure enclosure, tested by following EN-DIN 60079-2 and the pressure controller QSS. Inside the enclosure, a constant overpressure in the mbar area is execting, which is built up with the help of instrument air or inert gas, prevents the penetration of explosive atmosphere. This approach creates an ex-free zone within the potentially explosive environment in which non-ex devices can be used.Two variants are available:1. The overpressure enclosure can be supplied together with the pressure controller QSS and works 'ready to plug'.2. If a suitable overpressure enclosure is available, it can be set up together with the pressure monitor unit QSU to an overpressure system QSS. Acceptance is carried out in both cases after construction. This means that the user mounts his fittings on the mounting plate and performs the wiring. The free measurement during commissioning is carried out by a stationary gas warning device. After successful measurement, the power supply for the QUINGUARD® is activated. When the internal pressure is reached, all fixtures are switched on.Nicht Ex Geräte können mit Hilfe eines nach EN-DIN 60079-2 geprüften Überdruckschaltschrank und dem Druckwächtersystem QUINGUARD® QSS sicher in einer explosionsgefährdeten Umgebung betrieben werden. Im Inneren des Raumes wird durch einen ständigen Überdruck im mbar Bereich, der mit Hilfe von Instrumentenluft oder Inertgas aufgebaut wird, das Eindringen explosionsfähiger Atmosphäre verhindert. Durch diese Vorgehensweise wird innerhalb der explosionsgefährdeten Umgebung eine Ex freie Zone geschaffen in der Nicht Ex Geräte zum Einsatz kommen.Das Freimessen bei der Inbetriebnahme wird durch ein stationär eingebautes Gaswarngerät durchgeführt. Nach erfolgreicher Messung wird die Spannungsversorgung für den QUINGUARD® freigeschaltet. Wird der Innendruck erreicht werden alle Einbauten zugeschaltet. Show less

Education

  • LAUDA DR. R. WOBSER GMBH & CO. KG
    1986 - 1989

Community

You need to have a working account to view this content. Click here to join now