Md.Moshiur Rahman
Assistant Engineer ( Power ) at Mir Telecom Limited- Claim this Profile
Click to upgrade to our gold package
for the full feature experience.
-
English -
Topline Score
Bio
Experience
-
Mir Telecom Group
-
Bangladesh
-
Telecommunications
-
1 - 100 Employee
-
Assistant Engineer ( Power )
-
Jul 2009 - Present
Responsibilities: 1. I have good experience of Large capacity Data center and power system Installation, commissioning, power Monitoring with various type MUX ,server installation, optical fiber lay etc. 2. Maintenance of industrial AVR: 200kva, 415 volts 3phase input Main power line from DPDC. 3. Maintenance of Sub-station: 630KVA & 400kva 2 unit With including HT, LT Panel, PFI Plant with sub-energy meter etc.4. Maintenance & service of 220 kva, 365kva, 65kva, 110kva various capacities diesel Generator (Comfort Turbo). Lube oil filter, Fuel filter, Air-filter, 24VDC Battery, Radiator all are mechanical External & internal problem solving. Monitoring & Supervision of starting system and Control panel. 5. Planning ,distribution & installation of the various type electrical equipment's like as ATS, Manual Change over All kinds of Circuit Breaker, EMDB, MDB, SDB & maintain their log sheet.6. Maintenance of Emerson & Agisson Rectifier 1000Amp capacity 6 unit and monthly maintain the log & health checkup for battery bank of every site.7. Maintenance and monthly checkup of D.C supply system & D.C distribution for all device connectivity with various type switch & telecom Equipment.8. Maintenance & Installation of industrial Online UPS 10 kva 17 unit and their Power distribution system for IGW, ICX, IIG, Data center with various type Switch & Server.9. Planning of AC/DC power connection system and ground fault monitoring device with ensure equipment grounding and health checkup for ground connected divice. 10. i have good experience of HVAC system and monitoring of 7,2,0000 BTU capacity YORK (USA) central type air condition for large Data center & Emerson ( Leibart) Precision type 10 ton 3 unit, for switch room and General Brand various capacity 64 Unit Wall, cassette & ceiling Type. 11. Installation & monitoring of Fire Alarm detection system with positioning of Extinguishing ( CO2 & ABC ) cylinder and Automatic gas suppression system for FM-200 in Data center.
-
-
-
banglalink
-
Bangladesh
-
Telecommunications
-
700 & Above Employee
-
BSS Officer.(power)
-
Sep 2008 - Jun 2009
Responsibilities: Rectifier Testing &Maintenance ( EMERSON) Banglalink in 553 sites. • Maintenance of all power Equipment like as Generator, AVR, ATS, MDB, Air-condition in 443 sites. • BTS Installation, Commissioning & Maintenance ( Huawei (BTS-312, BTS-3012), in Banglalink Telecom. • Site Equipment Receive &Good handling. • DDF Installation and Grounding etc. • Power Connection Rectifier to DCDB to TRU, TRU to MW Equipment • Installation of Indoor and Outdoor Cable Tray • Coaxial Cable Installation, Making Connectors on Indoor and Outdoor, Taping, Grounding, Installation of Lightning Arrester and Fixing as Per Requirement Per Site. • Feeder Cable, Grounding, Connector Making, MW Radio and Rack Installation, Installation of Lightning Arrester and Fixing as Per Requirement Per Site. • Labeling for All Indoor / Outdoor Cabling And DDF. • Antenna System Installation, Tilting, Grounding and Coaxial connection for 1+1 HSB, according to plan. • Checking the Polarity of AC / DC Power Connections. • Rectifier and Battery Installation / Re-parenting (Necessary for Co-located Sites) • Feeder Plate Installation With Earth Bar • In Co-located Site Existing BTS, Rectifier, Power Supply, Battery, AVR Re-arrange and Re-installation.
-
-
Education
-
Green University of Bangladesh
Bachelor of EEE., Maintenance of all Electrical & Electronic Components