Mansoor Awan

Senior Substation design Engineer at EvoEnergy
  • Claim this Profile
Contact Information
us****@****om
(386) 825-5501
Location
Moncrieff, Australian Capital Territory, Australia, AU

Topline Score

Topline score feature will be out soon.

Bio

Generated by
Topline AI

You need to have a working account to view this content.
You need to have a working account to view this content.

Experience

    • Renewable Energy Semiconductor Manufacturing
    • 1 - 100 Employee
    • Senior Substation design Engineer
      • Apr 2021 - Present

    • New Zealand
    • Business Consulting and Services
    • 700 & Above Employee
    • Senior Power System Protection Engineer at BECA
      • Feb 2019 - Present

  • AECOM power
    • Sydney, Australia
    • Senior protection Engineer
      • Nov 2017 - Feb 2019

      Protection/ secondary System Design, Renewable Energy. Protection/ secondary System Design, Renewable Energy.

    • Senior protection Engineer
      • Nov 2016 - Sep 2017

      Relay settings calculation and protection design. Relay settings calculation and protection design.

  • Downer
    • Adelaide, Australia
    • Senior Protection Engineer
      • Jun 2012 - Nov 2016

      IEC61850 SUBSTATIONS Design and configuration of relays and BCU. Design of SLD,Protection concept & block logic diagrams, interlocking, schematics upto 275 kv substations. PROTECTION functions and logic testing OF Line, transformer, bus zone, coupler IED's and GOOSE Publisher/Subscriber testing. Management of project activities with design Manager and utilities representative. IEC61850 SUBSTATIONS Design and configuration of relays and BCU. Design of SLD,Protection concept & block logic diagrams, interlocking, schematics upto 275 kv substations. PROTECTION functions and logic testing OF Line, transformer, bus zone, coupler IED's and GOOSE Publisher/Subscriber testing. Management of project activities with design Manager and utilities representative.

    • Power System Protection Engineer+ Renewable Energy
      • Apr 2010 - Jun 2012

      Performing relaying and advanced power system analysis including system short circuit, load flow, relay coordination, motor Acceleration and Arc flash Hazard analysis using ETAP. Development and review of complete engineering design packages for protective relaying and communications systems, including AC one-line and three-line diagrams, DC schematics, logic and functional diagrams, panel layouts, interconnection diagrams, relaying equipment specifications Approval of contactors' schematics for the new substations and protection modification drawings for the remote end substation ends and issuance of relay setting calculations for substations and checking of contractors' relay setting-calculations and issue of the new protection settings Prepared Initiatives, strategic objectives and feasibility study of Smart grid technology in Saudi Aramco and working with the smart grid group in Saudi Aramco Prepared feasibility report of Solar and Wind Power in Saudi Arabia and currently working with the renewable energy group. Technical assistance of Power system protection issues to the field formation and fault analysis Show less

    • POWER SYSTEM PROTECTION ENGINEER
      • Nov 2002 - Mar 2010

      Preparation of protection and control schematics to deliver optimum security and dependability for 132kV up to 500kV substations. Able to establish pre-qualification of new protection equipment from world wide relays' Manufacturers and up dating the Relays Approved List. Approval of contactors' schematics for the new substations and protection modification drawings for the remote end substation ends and issuance of relay setting calculations for substations and checking of contractors' relay setting-calculations and issue of the new protection settings Reviewing of existing protection design & logic and deliver improvements in line with best industry protection practices Proficiency in testing & commissioning of protective Relays. Hands on experience to design the protection schemes of Thermal and hydel Power Plants. Strong experience in design review of technical submittals from various international contractors like SEL, Areva, M/s Siemens, M/s ABB, etc and implementation of these drawings at respective substations.. Show less

Education

  • University of Engineering and Technology, Lahore
    M.Sc, Electrical Engineering
    2004 - 2006
  • Lahore University of Management Sciences
    M.Sc, Computer Engineering
    2002 - 2004
  • University of Engineering and Technology, Lahore
    B.Sc, Electrical and Electronics Engineering
    1998 - 2002

Community

You need to have a working account to view this content. Click here to join now