Jitendra Vijayvargiya
Technical Support Engineer at RS Consultancy- Claim this Profile
Click to upgrade to our gold package
for the full feature experience.
Topline Score
Bio
Experience
-
RS Consultancy
-
United Kingdom
-
Marketing Services
-
1 - 100 Employee
-
Technical Support Engineer
-
Jul 2021 - Present
Installation & Commissioning of RTU & FRTU. Configurations of Schneider C264 RTU, Schneider Saitel RTU (HU_A & HU_BI), Teltonika TRB140/TRB245 Modem. Implementation of Modbus, IEC 60870-5-101/103/104, IEC 61850 Protocols for the integration to SCADA system. Worked on various relays like Ashida, Schneider (Vamp-300), ABB, CGL, Siemens, Micom P142 & P643 for the integration with RTU over IEC61850 Protocol. Preparation of IO lists for SCADA & ADMS. Co-ordination with vendors and contractors for smooth project execution. Performed SAT (Site Acceptance Test). Configured Relay I/O points for data acquisitions. Conducted P2P testing with Customer. Advantech RTU, ECU Configuration. ETAP iCE Gateway Configuration (Etap ice-cpu) Network Switch configuration (is5) AC UPS Signal, DC UPS Signal, EDG Signal (GCP), VFD Signal Configuration in ETAP Gateway & testing, Modbus (Rs-485 Communication). FEP Data Configuration. ETAP HMI Designing. Preparation of Dashboard. CID File Configuration in FEP & testing. Testing with Customer 11KV, 33KV BC , Incomer & feeder. Testing with Customer 415v Motor, Power Feeder, Breaker Feeder, ACB outgoing power feeder. KEP Server EX Software DCS Signal Configuration. Show less
-
-
-
Dongfang Electronics Co., Ltd
-
China
-
Software Development
-
1 - 100 Employee
-
Project Engineer
-
Dec 2013 - Oct 2020
Installation & Commissioning of RTU & FRTU. Configurations of DF1725 RTU/FRTU, Maestro E220 Series/M1003G Modem, Huawei router & Maiwe Router. Implementation of Modbus, IEC 60870-5-101/103/104, IEC 61850 Protocols for the integration to SCADA system. Worked on various relays like Ashida, Schneider (Vamp-300), ABB, CGL, Siemens, Micom P142 & P643 for the integration with RTU over IEC61850 Protocol. Preparation of IO lists for SCADA & ADMS. Integration of PSS/CSS/RMU/FPI/Sectionalisers with Power System Control Centre. Site survey & designing of as built drawing. Co-ordination with vendors and contractors for smooth project execution. Performed SAT (Site Acceptance Test), FAT (Factory Acceptance Test) & SAVT (System Availability Test). Installation & Commissioning of Weather Transducer. SCADA/DMS Application DF8000 & LDMS Application DF1800. Configured Relay I/O points for data acquisitions. CT & PT Connection work with MFM or MFT field. Conducted P2P testing with Customer. Prepared A-Z Documents. I&C Work of 2KVA UPS (Substation)& 40KVA UPS (DR/CC). Testing with Customer 11KV, 33KV BC , Incomer & feeder. Show less
-
-
Education
-
Rajiv Gandhi Prodyogiki Vishwavidyalaya
Bachelor of Engineering - BE, Electrical, Electronics and Communications Engineering