Jeremy Clark

Operations INLEC at Clough AMEC
  • Claim this Profile
Contact Information
us****@****om
(386) 825-5501
Location
Australia, AU

Topline Score

Topline score feature will be out soon.

Bio

Generated by
Topline AI

You need to have a working account to view this content.
You need to have a working account to view this content.

Experience

    • Australia
    • Oil and Gas
    • 100 - 200 Employee
    • Operations INLEC
      • Oct 2021 - Present

      Employed as an operations INLEC on the Bayu Undan FSO, associated duties include (but are not limited to): • Preventative and corrective maintenance, break downs, critical function testing, calibrations and detailed inspections of electrical and instrumentation in fire and gas detection, suppression and deluge systems, refrigeration and reliquification trains, power generation, UPS, DCS, PLC’s, cargo storage, inert gas generation, gas turbines, compressors, analysers, galley and living quarter equipment, hazardous area equipment, diesel generators, ship thrusters, mooring hooks, hydraulic and pneumatic valve systems. • Maintaining compliance with risk assessments and safe work instructions, actively identifying and controlling hazards to ensure Zero Harm for people, equipment and the environment, and working safely under site Permit to Work (PTW) and Lock Out/Tag Out (LOTO) systems. • Identifying critical tasks, planning accordingly, prioritizing high priority items first, identifying any technical issues. • Walking lines checking valve line-up to PID's • Reading OEM manuals and interpreting P&ID’s, schematics, wiring and termination diagrams and AS/NZS Standards to ensure tasks are completed to required specification and standards within tight time frames. • Detailed inspections and rectification of Ex Rated Electrical Equipment in Hazardous Areas (EEHA), as well as mark-up E&I loop drawings, and monitoring DCS/SCADA to provide feedback to Field Technicians. • Utilizing SAP CMMS for work order tracking, task scheduling, historic maintenance recording, and total inventory management. • Preparing PTW, Job Hazard Analysis (JHA’s) and isolation certificates. • Implementing isolations for intrusive electrical & process work and ensuring safe and effective return to service. • Compose detailed production records for visibility of plant performance and provide accurate shift handover report. • After action reviews for post job briefing with management & stakeholders. Show less

    • Australia
    • Oil and Gas
    • 1 - 100 Employee
    • Electrical & Instrumentation Technician - Maintenance
      • Apr 2021 - Oct 2021

      • Carry out full electrical and process isolations & purging for vessel entry, cleaning and inspection. • Air freeing and deisolation of process for return to service. • Critical and non-critical function testing of CSG wells, including calibration of temperature, pressure, level and control valves, cause and effect testing and PLC code up-grades, as well as assisting with testing of PSV’s, rebuilds and maintenance of gas engines, servicing of linear rod pump and progressive cavity pump drive heads, fault finding and diagnosis • Completing risk assessments, following safe work instructions and complying with all PTW, LOTO and HSEQ systems and procedures to eliminate or reduce risk to people, equipment and the environment, and holding meaningful safety interactions to raise awareness and enhance overall site safety culture (same for all roles below) • Working collaboratively with direct team members and multi-discipline site interfaces, maintaining a helpful attitude, working towards common goals, and focusing on the overall delivery of high-quality workmanship (same for all roles below) • Reading and interpreting technical data, drawings and standards such as data sheets, loop drawings, P&ID’s, schematics and AS/NSZ 3000, 3017 and/or 60079 standards to ensure site works are delivered to required specifications, and with correct materials (same for all roles below) • Identifying critical tasks, planning accordingly, tackling prioritized items first, troubleshooting technical issues, rectifying anything within my sphere of competency, and escalating anything outside of (same for all roles below) • Using SAP CMMS for work order tracking, task scheduling, maintenance requests, historic maintenance recording, and inventory management • Verification and installation of isolations for safe access to de-energised systems, and de-isolations for returns to service • Detailed inspections of Ex d and Ex n Rated Electrical Equipment in Hazardous Areas (EEHA). Show less

    • Australia
    • Utilities
    • 700 & Above Employee
    • Electrical & Instrumentation - Operator Maintainer
      • Feb 2020 - Apr 2021

      Employed as an E&I Operator/Maintainer, my core role duties included (but were not limited to): • P&ID walk-throughs, checking valve line-ups, first fill of vessels, nitrogen purging for air freeing of process piping and vessels, MEG transfer, filling and purging hot oil system, filling bio-reactors with Thiopaq Catalyst, chemical dosing, and fault finding and rectification of instrumentation • Responsible the operation, optimisation and general maintenance of sulphur handling plant, plant air, power and hot oil systems, H2s removal system, MEG and condensate systems, waste water removal, chemical delivery off loading, chemical dosing, draining of vessels, and centrifugal decanter maintenance • Executing routine performance checks/daily rounds, diagnostics, fine tuning, reporting plant breakdowns or abnormalities, keeping accurate production records, providing clear and concise shift handover reports, assisting with the execution of plant shutdowns, and ensuring the overall safe achievement of production targets in-line with design/operating limits • Authorised Isolator and Permit Issuing Authority, responsible for the design, verification and installation of safe process isolations, as well as de-isolating plant to ensure safe and effective returns to service • Reviewing SOP’s (Standard Operations Procedures) and work methods to identify opportunities for improvement. Show less

    • Australia
    • Engineering Services
    • 100 - 200 Employee
    • Electrical & Instrumentation Technician - Maintenance
      • Nov 2018 - Dec 2019

      As an E&I Maintenance Technician, role duties included (but weren’t limited to): • Installation, programming, calibration, termination, loop testing, functional testing, diagnostics, commissioning, start-up and preventative, breakdown and shutdown maintenance of these E&I systems and equipment at Talinga, Condabri (South, Central, North), Reedy Creek, Combabula, Euramba and Spring Gully, and at Reedy Creek and Condabri WTF’s:  Pressure, level, flow, temperature, vibration, fire and gas detectors and transmitters, as well as positioners, relays, controllers, safety critical and control valves, PLC’s, DCS, SCADA, SIS, UPS, VSD’s, MCC’s, ESD’s, DB’s, CB’s, HV and LV systems, substations, single and 3-phase motors, transformers, panels, earthing, and general power and lighting • Used Oracle and ISSoW systems to carry out instrumentation and control system calibrations, critical function testing, control valve commissioning and testing, gas compressor condition monitoring, flare maintenance and EEHA inspections • Installation, maintenance and detailed inspection of Ex d, Ex e, Ex Ia and b, Ex m, Ex n and Ex p Rated Electrical Equipment in Hazardous Areas (EEHA). • Completed and closes-out any outstanding maintenance work orders during planned TAR (Turnaround) events/shutdowns • Design, verification and installation of safe process isolations, and de-isolations for returns to service. Show less

    • Australia
    • Oil and Gas
    • 1 - 100 Employee
    • Electrical & Instrumentation Technician - Commissioning & Start-up
      • Nov 2017 - Nov 2018

      As an E&I Technician for CSU works, role duties included (but weren’t limited to): • Brownfield commissioning and handover of CSG wells, including upgrades and modifications to linear rod pumps, progress cavity pumps, VSD’s and RTU’s, punch listing, compilation and verification of dossiers, and redlining or greenlining drawings • E&I troubleshooting, function testing and loop testing, as well as the inspection, testing and commissioning of control systems, which included the use of FloBoss for commissioning of Emerson Delta V DCS and ROC 800 controllers • Developed and executed ITP’s (Inspection and Test Plans), ITR’s (Inspection and Test Records), FIC’s (Field Installation Checklists and NCR’s (Non Conformance Reports) • QA/QC of punch listed items, compilation and verification of dossiers, and redlining or greenlining drawings. Show less

    • Australia
    • Engineering Services
    • 100 - 200 Employee
    • Electrical & Instrumentation Technician - Maintenance
      • Feb 2016 - Nov 2017

      Carry out and complete Planed & Unplanned maintenance using Oracale maintenance system on Origin Energy’s gas process facilities, water treatment plants and well sites during normal operation and planned shut downs. Working under the ISSoW permit to work system to carry out critical function testing, hazardous area inspections, HV transformer testing, seal gas heater modifications, Yokogawa control system trouble shooting and fault diagnosing, instrumentation calibration (Fieldbus and HART), Siemens HV compressor repairs & maintenance, HV switching while keeping documents such as equipment registers, drawings and HA dossier up to date. Show less

    • Australia
    • Utilities
    • 700 & Above Employee
    • Electrical & Instrumentation Technician - Commissioning & Start-up
      • Aug 2014 - Sep 2015

      • Worked within APLNG Upstream Commissioning and Maintenance teams across Gas Processing Facilities and the 42” Export Pipeline, conducting installations and detailed inspections of Electrical Equipment in Hazardous Areas (EEHA), as well as commissioning and maintenance of solar power systems, and developing permits for standard and high-risk works • Used the DCS and various calibration and testing equipment (including hand pumps, process calibrators and 475 field communicators) to perform loop checks and calibrations on automatic line brake and control valves, temperature, pressure, level, flow and pig receiver transmitters, and diagnosed, rectified and/or reported any problems found • Developing and executing ITP’s, ITR’s, FTP’s and NCR’s, as well as QA/QC of punch lists, compilation and verification of dossiers, and redlining or greenlining of drawings • Inspection and rectification of Ex d, Ex e, Ex Ia and b, Ex m, Ex n and Ex p Rated Electrical Equipment in Hazardous Areas • Design, verification and installation of safe process isolations, and de-isolations for returns to service. Show less

    • Australia
    • Civil Engineering
    • 700 & Above Employee
    • Electrical & Instrumentation Technician - Maintenance
      • May 2013 - Jun 2014

      Develop work packs and permits to carry out the installation and maintenance of electrical and instrumentation wiring, distribution and control systems. Testing, recording and managing results. Deciphering loop, single line, engineering and PID drawings of various instrument and electrical designs and applications. Hazardous area inspections and the complication of inspection and test records. Commissioning and dynamic testing of valves, transmitters, instruments, fieldbus and PLC’s using the DCS and completing electrical and EEHA dossiers on the Woodside Pluto LNG Gas Plant. Show less

    • Australia
    • Industrial Machinery Manufacturing
    • 300 - 400 Employee
    • Electrical & Instrumentation Technician - Commissioning
      • Jan 2013 - Apr 2013

      Permit holder and authorized isolator in the pre-commissioning team working on an FMG iron ore process facility including, circuit verification, cable testing, field bus termination and testing, mechanical inspections of electrical & instrumentation devices and Loop Checking which also involved completing test reports and redline drawings. Permit holder and authorized isolator in the pre-commissioning team working on an FMG iron ore process facility including, circuit verification, cable testing, field bus termination and testing, mechanical inspections of electrical & instrumentation devices and Loop Checking which also involved completing test reports and redline drawings.

    • Oil and Gas
    • 1 - 100 Employee
    • Electrical & Instrumentation Technician - Maintenance
      • Jan 2012 - Apr 2012

      Working within the major maintenance department to identify corrective maintenance tasks, develop and hold permits to carry out service, repairs, inspections, calibration, commissioning and complete test records, of hazardous areas electrical and instrumentation apparatus on LNG process trains and associated infrastructure within safety standards and procedures on the Woodside Karratha Gas Plant. Working within the major maintenance department to identify corrective maintenance tasks, develop and hold permits to carry out service, repairs, inspections, calibration, commissioning and complete test records, of hazardous areas electrical and instrumentation apparatus on LNG process trains and associated infrastructure within safety standards and procedures on the Woodside Karratha Gas Plant.

    • United Arab Emirates
    • Engineering Services
    • 700 & Above Employee
    • EEHA Electrician - Construction & Commissioning
      • Jun 2010 - Dec 2011

      Installation and commissioning of lights, power outlets, motors, fieldbus, various instrumentation and all types of hazardous area equipment. Complete variations, defects and hazardous area inspections. Installation and commissioning of lights, power outlets, motors, fieldbus, various instrumentation and all types of hazardous area equipment. Complete variations, defects and hazardous area inspections.

  • Karratha Electrical & instrumenttion
    • Woodside, Pluto Gas Plant
    • Electrician - Construction
      • Oct 2009 - Jun 2010

      Provide electrical services on the Pluto LNG onshore project in WA and work in a team ranging between two to eight at any given time. This involves various duties including electrical testing and tagging; electrical testing and commissioning; cable tray; wiring of desalination plants; temporary power to site offices, crib rooms and so forth; termination of switchboards; preparation and completion of assorted paperwork including permits to work, job safety analysis, test and inspection reports and daily work records. Show less

    • Finland
    • Industrial Machinery Manufacturing
    • 700 & Above Employee
    • Elevator Technician - Construction & Maintenance
      • 2007 - 2009

      Electrical installation, service and repair of elevators and mechanical fabrication. The electrical installation component consisting of fault finding, wiring, testing and commissioning. Mechanical component consisted of fabrication, guide rails, elevator car and counter weight, roping and finial compliance testing. Provided high level customer service to builders on how to rectify issues in the quickest most streamlined way whilst adhering to quality standards, provided technical advice to builders and property managers regarding the servicing, maintenance and rectification of faulty elevators, and provided emergency response services for members of the public that were trapped in elevators. Show less

Education

  • Pilibara Tafe
    Instrumentation
    2011 - 2011
  • Mt Gravatt TAFE
    Electrotechnology
    2004 - 2008
  • Victoria Point State High School
    Senior Certificate
    1998 - 2002

Community