      • Nov 2017 - Present

      KSJV a joint venture between Kentech Australia and Southern Cross Electrical Engineering. KSJV is contracted to complete pre commissioning and commissioning of Chevron’s Wheatstone LNG facility. Project work scopes include; • Execute and record commissioning activities, including high voltage testing, insulation and integrity testing, switchgear testing, transformer testing, meter & relay testing, motor runs, walk-downs, and electrical physical checks. • Prepare CSU electrical isolations, switching and energisation documents. • Uphold site safety procedures including: PTW, STARRT, JHA, LOTO and HV access. • Fault-find and trouble shoot engineering issues including rectification works. • Complete schematic function tests on electrical systems including redline drawings.

    • EEHA Electrician / HV Cable Terminator
      • Nov 2016 - Nov 2017

      EEHA/HV Electrician completing HV Cable upgrade project for Origin Energy, Combabula GPF, Orana GPF, Condabri South GPF QLD • Installation & Termination of 6.6kv cable and earthing. • Develop & Implementation of ISSOW Origin permits systems for all job tasks. • EEHA HV cable glands and terminations. • Major cable tray installation. EEHA/HV Electrician completing HV Cable upgrade project for Origin Energy, Combabula GPF, Orana GPF, Condabri South GPF QLD • Installation & Termination of 6.6kv cable and earthing. • Develop & Implementation of ISSOW Origin permits systems for all job tasks. • EEHA HV cable glands and terminations. • Major cable tray installation.

    • United States
    • Construction
    • 700 & Above Employee
    • Senior Lead Hand Electrician
      • Jul 2014 - Nov 2016
    • Australia
    • Mining
    • 700 & Above Employee
    • Electrical Maintenance Foreman
      • Aug 2011 - Jul 2014

      •Manage the daily operation of the Electrical Maintenance Crew Area in a safe and efficient manner •Plan and execute tasks using available manpower, tools and materials in the most cost effective and efficient manner •Ensure that Departmental records are maintained, e.g. work orders, project files and break down analysis •Ensure that crews daily work plans are executed in conjunction with set and variable priorities and those critical breakdowns are managed appropriately •Provide direction, on the job training and technical assistance for subordinates as required •Perform daily running inspections on critical equipment in the main Production area •Maintain communication and cooperation with operating departments •Ensure that all routine maintenance tasks are followed correctly and recorded and all alterations to any job plans are provided to the Planning Department so that plans can be altered. •Maintain safe working environment and practices for subordinates •Monitor and evaluate performance of subordinates •Mentor, motivate and maintain morale of the team •Report Daily activities to the Maintenance Superintendent – Electrical, Instrumentation and Controls

    • Papua New Guinea
    • Mining
    • 200 - 300 Employee
    • Technical advisor
      • 2011 - 2012
    • CHPP operator maintainer Electrician
      • Jul 2009 - Jul 2011

      General; In this position I had been responsible for; • Handling Raw Coal. Treat and dispose of reject and tailings • Monitor Coal Plant. Control Coal Operations • Conduct sampling operations • Perform plant maintenance • Operate front end loader ( Komatsu WA700, Cat 992C, Cat 992D, Cat 930G) • Plant isolations • Develop and execute preventative maintenance tasks for CHPP • Break down maintenance fault finding, reducing plant down time. • Continuous improvement of CHPP electrical, ensuring longevity of motors and electrical equipment, eliminating potential faults. • Instrumentation maintenance and calibration to ensure plant efficiency, highest yields and plant control accuracy.

    • Australia
    • Construction
    • 700 & Above Employee
    • CHPP Maintenance Electrician
      • Mar 2008 - Jul 2009