Ayaz Sarwer

Electrical Engineer at intec - GOPA-International Energy Consultants
  • Claim this Profile
Contact Information
us****@****om
(386) 825-5501
Location
United Arab Emirates, AE
Languages
  • English Professional working proficiency
  • Urdu Native or bilingual proficiency

Topline Score

Topline score feature will be out soon.

Bio

Generated by
Topline AI

You need to have a working account to view this content.
You need to have a working account to view this content.

Credentials

  • ADDC Competency to work on High Voltage
    ADDC_Abu Dhabi Distribution Company

Experience

    • Germany
    • Oil and Gas
    • 200 - 300 Employee
    • Electrical Engineer
      • Jan 2016 - Present

      Project #1 Nibras Medium Voltage (33kV) Cable Supply and InstallationContract No: 2340650- (ARE) Assistant Resident Engineer for Nibras Project - involving design/material submittal review and site supervision for 33/11kV substation installation works with associated cable laying works.- Scope of responsibilities: Site survey, Micro planning and execution including getting NOCs and approvals from authorities, coordination for shutdown works, implementing AADC System Safety Rules (SSR). - Route survey, mapping, design support for power supply engineering works.- Supervision of Remote end modification works at Salamat GS. - Supervision of 33KV cable installation for Aerospace Holding Company.- Approves as built Drawings, red mark Drawings and RCDR MIR WIR of contractor. Show less

    • Substation Engineer
      • Jun 2014 - Dec 2015

      PROJECT # 2: Data Collection, Condition Monitoring & Data Entry in all Substations of all RegionsContract No: D102390CONDITION MONITORING:- As AADC approved Competent Person responsible for receiving Safety permit-LAP & PTW to execute data collection and condition monitoring work.- Partial Discharge testing of transformer HV cable box, switchgear cable box, bus bar section, CB section, QRM cable box, TRM cable box.- PD Measurement in Ultrasonic mode for transformer HV cable box, switchgear cable box, bus bar section, CB section, QRM cable box, TRM cable box.- Have good experience of TRM, QRM, TR, SWS and SWGr Condition Assessment.- Thermal inspection of HV Cables and Bus Bar sections.- Reporting of Civil condition of substations.DATA COLLECTION DETAILS:- Updating AADC assets details in CMMS (Computerized Maintenance Management System) for any deviations and same will be corrected, updated and closed for the work orders.- Taking technical data of Transformer, Switchgear, TRM, QRM, LV panel from specification name plate- Updated data for all substations in ADDC Maximo.- I have done almost 1500 substations and Switching Stations- Condition Monitoring and Data Collection of Abu Dhabi City (East, West and Central Region)- Valid Competency certificate for 11KV from ADDC.- Performed almost 1500 substations Partial discharge and Thermal Imaging for Condition Monitoring Project.- Performed Data Entry for these substations through HHU (Hand Held Unit). Show less

    • United Arab Emirates
    • Utilities
    • 700 & Above Employee
    • Electrical Engineer
      • Jan 2013 - Jun 2014

      - Have good experience of High Voltage Emergence Repair in busy Area (Madina Zayed Abu Dhabi). - Competent to work in High voltage (ADDC Certification). - Scope of responsibilities: Site survey, Micro planning and execution including coordination for shutdown works, implementing ADDC System Safety Rules (SSR) as ADDC approved Competent Person responsible for receiving Safety documents - LAP & PTW. - Preventive maintenance of switchgears, Distribution Transformers and HV cables. - Capable of HV cable fault locating using testing van (Impulse Reflection Method, Secondary Impulse Method/ Multiple Impulse Method (SIM/MIM), Impulse Current Method, Decay Method, Burn down Techniques, Bridge Measurement). - Operation of 11KV Substation-Switchgears (Siemens, Schneider electric, ABB, Siemens, Lucy etc.) - Maintinance and Testing of Transformer, Switchgear, HV Cable and Protection system. - Transformer testing (insulation resistance, voltage ratio, phase displacements, separate source power frequency voltage withstand test , induced overvoltage withstand test ,No load loss No load current , Measurement of winding resistance , Short circuit impedance and Load losses ). - Troubleshooting of HV CB Closing-Opening and other critical faults. (Using Wiring Diagram) - Expertise in Maintenance,testing of transformer (Pressure Test/hi-pot test) and Switchgear. - Maintenance and Operation of Circuit Breakers (Sulfur hexafluoride (SF6), Vacuum type, oil type). - Overhauling and reconditioning of Power Transformers of various power rating 1000, 1500KVA etc. - CT VT (instrument transformer) testing, replacing and troubleshooting. - Capable to pre-locate and tracing high voltage cable fault using digital instruments Test Van. - Capable to make emergency plans, procedures for HV repairing. - Ability to operate MAXIMO system. - Expert to operate All Electrical Instruments (Digital Insulation Tester, Digital Ratio meter, Hi-potential Test equipment, Digital Ohm meter and Power Meter). Show less

Education

  • University of Azad Jammu and Kashmir
    Bachelor of Science (BSc), Electrical Engineer
    2007 - 2011
  • kashmir model college
    azad jammu kashmir university, Pre-Engineering
    2005 - 2007

Community

You need to have a working account to view this content. Click here to join now