      September 2019 - Present Archemica Co.,LTDTitle Sales Executive-Sale HPLC Under Brand Thermo Scientific-Sale HPLC for New Customer-Find New Customer Contract and Present HPLC-Send Brochure and Promotion HPLC via E-mail to New Customer-Send Quotation HPLC Instrument and Specification Follow Customer Request-Present HPLC Feature and Present Software Function Present specification -Present Application of sample detection by Themo scientific for reference document -Testing sample of new customer to confirm a performance of HPLC system-Give an Advance After Sale Service

    • Thailand
    • Biotechnology Research
    • 1 - 100 Employee
    • Service Engineer
      • Jun 2012 - Mar 2019

      June 2012-March 2019 Barascientific Co.,LTDTitle Service Engineer Spectrophotometry group (AA FTIR ICP) 2012-2015Job Install AAS1)Unlock 2) Install Gas Acetylene (C2H2) 3) Install Air Compressor 4) Set Acetylene (C2H2) Gas Pressure at 1Bar 5)Set Air Pressure at 3.5Bar 6) Test System Operation AAS 7) Install Computer 8) Install UPS 9) Install Software AA Wizard 10) Test Communication of System with Software 11) Test Controlling of AAS system with Software Job Preventive Maintenance/Calibrate AAS1)Check Life Time of Spare Part / Consumable Part 2) Clean AAS Cover 3) Clean Burner Head Nebulizer Chamber Mixer 4) Calibrate and maintenance follow by the protocol Job Repair AASJob Replace spare part AASJob Install FTIR 1)Unlock 2) Install Beam Splitter 3) Install Window KBr 4)Test System Operation FT-IR 5) Install Computer 6) Install UPS 7) Install Software IR-Solution 8)Test Communication of System with Software 9) Test Controlling of FT-IR with Software Job Preventive Maintenance/Calibrate FT-IR1)Clean FT-IR Cover 2) Clean Beam splitter Moving Mirror Fix Mirror Window KBr 3) Checking vaporization of Beam Splitter Moving Mirror Fix Mirror Window KBr 4) Replace Silica Gel 5) Calibrate and maintenance follow by protocol Job Repair FT-IRJob Replace spare part FT-IRService Engineer Chomatography Group (HPLC) 2015-2019Job Install HPLC 1)Install Degasser LPGE-Unit Pump Autosampler Oven Detector 2) Test System Operation of Degasser LPGE-Unit Pump Autosampler Oven Detector 3) Install Computer 4) Install UPS 5) Install Software Lab-solution 6) Set Config HPLC 7) Test Communication of System with Software 8) Test Controlling HPLC with SoftwareJob Preventive Maintenance/Calibrate HPLC1)Clean HPLC Cover 2) Clean Element Filter Check valve in Check valve out Mixer Filter LVP Rotor HPV Rotor 3) Check Life Time of Spare Part / Consumable 4) Calibrate and maintenance follow by protocol Job Repair HPLCJob Replace Spare Part HPLC

Education

  • Kingmongkut Institute of Technology Ladkrabang
    Bachelor of Science, Chemical Industry Analytical Instrument
    2006 - 2010
  • สถาบันเทคโนโลยีพระจอมเกล้าเจ้าคุณทหารลาดกระบัง
    ปริญญาตรี, เคมีอุตสาหกรรมเครื่องมือวิเคราะห์
    2006 - 2010

Community

You need to have a working account to view this content. Click here to join now