Anbarasan manokaran
Maintenance supervisor (generator) at Servtech International for Oil Services L.L.C- Claim this Profile
Click to upgrade to our gold package
for the full feature experience.
Topline Score
Bio
Experience
-
Servtech International for Oil Services L.L.C
-
Oil and Gas
-
1 - 100 Employee
-
Maintenance supervisor (generator)
-
Jul 2018 - Present
* POWER GENERATIONS : Standby diesel power plant maintenance and operation for HAMAD INTERNATIONAL AIRPORT. Caterpillar 3616 model engine. *diesel power plant maintenance and operation for BANANA ISLAND RESORT - Cummins generator 8 * 2000kva and 1600 KW. Qsk60-g4 2013 models. * SWITCHGEAR - generator synchronization and totalizing panels.. Make Schneider electric. * CONTROLLER - Deep sea electronics. generator controller DSE 8610 and busbar controller 8680. * SCADA MONITOR - generator and synchronization panel total monitoring control for intelivision 17 touch display. generator control intelivision 8 touch and related modem and ethernet switch controls.. * TRANSFORMER - power and Distribution Transformers (11kv /6.6kv) (11kv / 440v) and (440v / 11kv). transformer temperature control and fan controller VRT 600 AND NT 935. make tec system. * NGR - NGR SE-325 monitor ground fault and sensing resistor using 8400 vca. Make little fuse STARTCO. * BREAKERS - LT - ACB H2 type breakers 3200 A to 5000A and HT - VCB VHIH type breakers rated voltage 12 kv and rated current 630 A. Make Schneider and tamco. *RMU SYSTEM - 11* 1600kva distribution transformer connected in ring main unit T system and using with arc reducing sf6 gas Production with earth fault indicators.. Show less
-
-
-
Jaidah Group
-
Qatar
-
Retail
-
500 - 600 Employee
-
Electrical maintenance foreman
-
May 2018 - Jul 2018
*LT panel control wiring. *VFD panel control wiring. *MDB, LDB, MLDP, EMLDB, ELDB, PDB, panel making and control wiring. *CAPACITOR BANK control wiring *DOL starter and STAR DELTA starter control wiring *BUS BAR assembling *all type of conductor and relays switching devices *LT panel control wiring. *VFD panel control wiring. *MDB, LDB, MLDP, EMLDB, ELDB, PDB, panel making and control wiring. *CAPACITOR BANK control wiring *DOL starter and STAR DELTA starter control wiring *BUS BAR assembling *all type of conductor and relays switching devices
-
-
-
Petrofac
-
United Kingdom
-
Engineering Services
-
700 & Above Employee
-
Electrical Technician
-
Mar 2016 - Mar 2018
* GC29 PROJECT - Maintenance of Power and Distribution Transformers (11kV/440v 1600KVA) with their Relative Switch Gears. Preventive, Breakdown and Periodical and Annul maintenance. *CIRCUIT BREAKERS - Preventive, Breakdown and Periodical maintenance of VCB’s up to 11KV, and ACBs up to 415V. *PROTECTION SYSTEM - Testing, Trouble shooting and Maintenance of protection relays [Electro dynamic as well as static relays] and programming of MICOM, MOTPRO relays [microprocessor based]. *SWITCH GEAR - Maintenance of MV and LV Switch Gear’s (11kV, 3.3kand440v). Prevent maintenance of L.T. Motor’s and H.T. (11 kV). LT & H.T Motors of L.T. Motors up To 132 KW, 6.6kV 4930 KW. Maintenance of HT and LT switchgears [11KV, 6.6 KV 3.KV, 440V]. Especially Schneider, L&T, ABB and Siemens, Breakdown Periodical maintenance and over-hauling of HT and LT motors. * BATTERY SYSTEM - Maintenance of Batteries and their charger systems voltage level of 440V, 110V. *VARIABLE SPEED DRIVE - Operation and maintenance of Variable speed drives with the capacity from 0.5 KW – 160 KW. Siemens, ABB, Schneider * CABLES - Knowledge about XLPE,XLPE SC,LC and NON LC cables, FRLS, PVC cables and their terminations and testing of cables including MEGGER test, Control and Power Cable Glanding and Termination LT Cable up 240 Sqmm,HT cable 300sqmm.Lighti Circuit.Cable lying and try fixing. LT Cable straight joint up to 300 Sqmm.Troubleshooting of Plant and Street lights, Power system analysis in single phase & three phase by using FLUKE power quality analyser. Show less
-
-
-
Chennai Petroleum Corp Limited (CPCL), formerly known as Madras Refineries Limited (MRL)
-
India
-
Utilities
-
200 - 300 Employee
-
Electrical Technician
-
Mar 2014 - Feb 2016
POWER GENERATION - Job allocation in Refinery’s and Co-Generation Power plant TG (2 X 20MW) TRANSFORMERS - Maintenance of Power and Distribution Transformers (11kV/440v 1600KVA) with their Relative Switch Gears. Preventive, Breakdown and Periodical and Annul maintenance. CIRCUIT BREAKERS - Preventive, Breakdown and Periodical maintenance of VCB’s up to 11KV, and ACBs up to 415V. PROTECTION SYSTEM - Testing, Trouble shooting and Maintenance of protection relays [Electro dynamic as well as static relays] and programming of MICOM, MOTPRO relays [microprocessor based]. SWITCH GEAR - Maintenance of MV and LV Switch Gear’s (11kV, 3.3kand440v). Prevent maintenance of L.T. Motor’s and H.T. (11 kV). LT & H.T Motors of L.T. Motors up To 132 KW, 6.6kV 4930 KW. Maintenance of HT and LT switchgears [11KV, 6.6 KV 3.KV, 440V]. Especially Schneider, BHEL, L&T, ABB and Siemens, Breakdown Periodical maintenance and over-hauling of HT and LT motors. BATTERY SYSTEM - Maintenance of Batteries and their charger systems voltage level of 440V, 110V. VARIABLE SPEED DRIVE - Operation and maintenance of Variable speed drives with the capacity from 0.5 KW – 160 KW. Siemens, ABB, Schneider. CABLES - Knowledge about XLPE,XLPE SC,LC and NON LC cables, FRLS, PVC cables and their terminations and testing of cables including MEGGER test, Control and Power Cable Glanding and Termination LT Cable up 240 Sqmm,HT cable 300sqmm.Lighti Circuit.Cable lying and try fixing. LT Cable straight joint up to 300 Sqmm.Troubleshooting of Plant and Street lights, Power system analysis in single phase & three phase by using FLUKE power quality analyser. Show less
-
-
-
Indian Oil Corporation Limited
-
India
-
Oil and Gas
-
700 & Above Employee
-
Electrical Technician
-
May 2013 - Feb 2014
*TRANSFORMERS - Maintenance of Power and Distribution Transformers (11kV/440v 1600KVA) with their Relative Switch Gears. Preventive, Breakdown and Periodical and Annul maintenance. *CIRCUIT BREAKERS - Preventive, Breakdown and Periodical maintenance of VCB’s up to 11KV, and ACBs up to 415V. *SWITCH GEAR - Maintenance of MV and LV Switch Gear’s (11kV, 3.3kand440v). Prevent maintenance of L.T. Motor’s and H.T. (11 kV). LT & H.T Motors of L.T. Motors up To 132 KW, 6.6kV 4930 KW. Maintenance of HT and LT switchgears [11KV, 6.6 KV 3.KV, 440V]. BHEL, L&T. *BATTERY SYSTEM - Maintenance of Batteries and their charger systems voltage level of 440V, 110V. *VARIABLE SPEED DRIVE - Operation and maintenance of Variable speed drives with the capacity from 0.5 KW – 1600 KW. Siemens, ABB, Schneider. *CABLES - Knowledge about XLPE,XLPE SC,LC and NON LC cables, FRLS, PVC cables and their terminations and testing of cables including MEGGER test, Control and Power Cable Glanding and Termination LT Cable up 240 Sqmm,HT cable 300sqmm.Lighti Circuit.Cable lying and try fixing. LT Cable straight joint up to 300 Sqmm.Troubleshooting of Plant and Street lights, Power system analysis in single phase & three phase by using FLUKE power quality analyser. Show less
-
-
Education
-
Manali Ramakrishna Polytechnic collage, Thanjavur
diploma, 10th