Amol Gaikwad

Team Leadar at Phadnis infrastructure LTD
  • Claim this Profile
Contact Information
us****@****om
(386) 825-5501
Location
Pune, Maharashtra, India, IN

Topline Score

Topline score feature will be out soon.

Bio

Generated by
Topline AI

You need to have a working account to view this content.
You need to have a working account to view this content.

Experience

    • Team Leadar
      • Jan 2010 - Present

      A) Nokia BTS.For Solapur Cluster• Installation of ID & OD BTS Flexi ,Metro ,Mini BTS their hardware configuration like interfacing multicoupler,TRX,Combiner,Duplexer and mounting of cards like power cord, bb2f cord BOI cord ,RRI /E1-T1cord,FIU .• RFI Site Survey (SDR,Site Lay Out, Site Snaps & RFI Check List,etc)• Performing BTS Expansion, Sector addition. Routing of RF and IF cable and connector at proper position.• Electrical down tilting of GSM antenna.• Releasing E1 from far end site and terminating it in near end site.• Assigning traffic (TCH), OMU signaling & TRX signaling in different time slots of E1 according to hardware comfit of BTS.• Having knowledge of microwave link matching and antenna alignment process (0.3, 0.6, 1.2, 1.8 & 2.8) etc.• Installation & commissioning of Nokia BTS.B) PMC Wireless CCTV project:• Responsible for Designing, construction, configuration and commissioning of CCTV Network.• Installation, commssioning & maintainance of Proxim MP-8100 base station and Proxim 8150 SU and AP-4000 to create a wireless network.• Designed the site drawings and installed the system accordingly on the plans drawn earlier.• Planning link capacity in relation to network topology and connectivity.• Supply the customer with Technical report to describe any fault to Proxim, Bosch HW or SWOptimization & Planning Support.C) BSNL DSLAM Project: • Installation, Configuration and Commissioning of BSNL Huawei DSLAMs (MA5600T and MA5616) in Maharashtra, Karnataka & Goa Circle.• Software Up gradation, VLAN Configuration and Bandwidth testing after Commissiong of DSLAMs. Also ADSL and VDSL Modem Testing.• Documentation of all Installation & Configuration Reports.• Daily planning for Installation & Configuration from BSNL.

    • India
    • Machinery Manufacturing
    • Organization
      • May 2008 - Present

      Working as Installation & Services Engineer. In this company to install all products in all India level. Major products are installing in telecom sector, these products are use in automation, control and remote monitoring system. Our clients are VODAPHONE, AIRTEL, IDEA, and BSNL, GTL. We are using these type of product AIUS (PIU), RMS, RSS, Fuel Sensor, Fire Alarm System. AIUS is using for power and control system of tower, RMS & RSS are using for remote monitoring of mobile tower system, Fuel Sensor show the present condition of fuel. Vehicle tracking system is using for monitor the vehicle position.AC Controller, DG Controller, AMF Panel, Servo. Fire alarm control panels (FACP) are fire alarm control systems mainly used for detecting fire and thereby raising an alarm.

    • Industrial Machinery Manufacturing
    • 1 - 100 Employee
    • Production Engineer
      • Jan 2007 - Present

      Working as a for automation control panels Production of electrical panel like- AMF, Duel AMF Panel, Engine panel, Power panel. AMF panels are used to automatically changeover from mains electricity supply to stand-by generator or genset on failure of the mains supply. Our clients are Kirloskar and Cummins in Pune.

    • Production Engineer
      • Jun 2004 - Present

      Worked as a Production Engineer for Automation Control Panels in Production of Electrical Panel like- AMF, Engine panel, Power panel, and AMF panels are used to automatically changeover from mains electricity supply to stand-by generator or genset on failure of the mains supply. Our client is Kirloskar Oil & Engines Limited in Pune.

    • testing Engineer
      • Apr 2003 - Present

      Quality control and Testing of Ballast P.C.B. and visual inspection of electronic products. Handling the complete process of quality and testing department. This P.C.B.s is used as Energy sever card specially used in TUBE LIGHTS & CFL BULBS.

    • India
    • IT Services and IT Consulting
    • 1 - 100 Employee
    • Installation & Service Engg.
      • May 2008 - Dec 2009

      Organization : Powertech Automation Solutions Pvt. Ltd. Pune. Duration : May-2008 to Dec -2009 Designation : Installation &Service Engineer

    • Installation &Service Engineer
      • May 2008 - Dec 2009

      Working as Installation & Services Engineer. In this company to install all products in all India level. Major products are installing in telecom sector, these products are use in automation, control and remote monitoring system. Our clients are VODAPHONE, AIRTEL, IDEA, and BSNL, GTL. We are using these type of product AIUS (PIU), RMS, RSS, Fuel Sensor, Fire Alarm System. AIUS is using for power and control system of tower, RMS & RSS are using for remote monitoring of mobile tower system, Fuel Sensor show the present condition of fuel. Vehicle tracking system is using for monitor the vehicle position.AC Controller, DG Controller, AMF Panel, Servo. Fire alarm control panels (FACP) are fire alarm control systems mainly used for detecting fire and thereby raising an alarm.

    • United Kingdom
    • Retail Office Equipment
    • Organization : R
      • Jun 2004 - Dec 2006

Education

  • Shnide Highschool ,Tuljapur,Dist.Osmanabad
    BSc &Diploma inElectronics& Communications., Electronics
    2006 - 2009
  • Govt. Polytechnic Osmanabad
    Diploma; M.S.B.T.E MUMBAI, Electronics & Communication; Maharashtra
    -
  • BAMU University, Aurangabad
    BSc, Electronics
    -

Community